Replacing Internal Tubes in Aqua-6 Ozone Generator

Aqua-6 Technical Walkthroughs

how to replace internal tubes in aqua 6 ozone generator air water oil applications

If the diffuser stone is placed more than 4 inches deep into the water, the air compressor pressure and water pressure will equalize. If this happens, it will damage the internal tubes.

NOTE: Never place the diffuser stone more than 4 inches deep in water.

When the unit is working but does not produce ozone, you may need to unplug the unit and open the back case to check for damage to these two internal tubes.

To replace the unit's internal tubes:

  • Please unplug the unit before beginning.
  • Open the 6 screws on the back of the Aqua-6. 
  • Four of the screws are located under soft pads. 
  • The additional two are located in the center. 
  • Check inside the unit for damage to the tubes. 
  • If the tubes are cracked, ruptured or have become hardened, they will need to be replaced. 

NOTE: When replacing the internal tubes, do not remove any electrical wire ties. Any loose wires inside the unit will cause damage to the unit or will cause an electrical short.

To purchase an Aqua-6, click here.



Older Post Newer Post


Leave a comment

Please note, comments must be approved before they are published

Related Posts

MP Series Maintenance Guide
MP Series Maintenance Guide
The MP Series requires occasional maintenance to keep the unit working properly. Use these guidelines from our Head Tech
Read More
Using Aqua-8 with Fish Tanks
Using Aqua-8 with Fish Tanks
  The upgraded Aqua-8 Multi-Purpose Ozone Generator can be used to keep fish tank water clear and odor free. The unit co
Read More
Replacing Air Pump in MP Series
Replacing Air Pump in MP Series
Follow this technical walkthrough to replace the air pump in the MP Series ozone generator. This will be the same proces
Read More